EdgeDesk.
← Research library

ES · Research follow-up

Does checking an intraday signal less often make it steadier?

What we asked, and what happened

Can the same intraday direction-and-momentum signal look steadier simply because we check it less often? Yes. Across 342 matched ES daytime sessions, checking every minute produced 12.57 uninterrupted periods per day. Checking only every 15 minutes, and keeping that decision until the next check, produced 3.66.

The middle observed period grew from 4 minutes to 45 minutes. But the slower schedule deliberately ignores what happens between checks. A longer-lived permission label does not show that it predicts price better.

This is a follow-up to our first momentum-filter comparison. It uses the same source data, indicator settings and eligible dates. The calculation was rerun and the period counts were checked separately; this is not a second independent market sample.

1. Keep the calculation the same; change when we act on it

ES is the E-mini S&P 500 futures contract. We use completed one-minute closing prices for both versions. There are two inputs: direction, measured by the change in a smoothed price average, and momentum, measured by the latest price compared with one hour earlier.

An EMA, or exponential moving average, is a running average that gives more weight to recent prices. Here its length is 1,200 one-minute observations:

New EMA = previous EMA
          + (2 / 1201) × (new minute close − previous EMA)

Direction change = latest EMA − EMA 180 observed minute candles earlier
Momentum = latest completed minute close − close 60 clock minutes earlier

IF direction change > 0 AND momentum > 0:
    allow long entries
ELSE IF direction change < 0 AND momentum < 0:
    allow short entries
ELSE:
    allow no new entries

“Long” means permission to buy; “short” means permission to sell in anticipation of a decline. If either input is exactly zero, permission is neutral: no new entries. This is an entry-permission label, not an instruction to exit an existing position.

Check every minute

After each minute finishes, use its newly calculated decision. A pause or a direction change can take effect every minute.

Check every 15 minutes

Read that exact same minute-based decision at :00, :15, :30 and :45. Keep it until the next check, even if the underlying signal changes.

At a quarter-hour check:
    stored decision = current minute decision
Between checks:
    use stored decision

We hold the entire decision, including neutral readings. We do not rebuild the EMA from 15-minute candles, skip a neutral check, or require two confirming checks.

All clock times are America/New_York, including daylight-saving changes. The minute candle starting at 10:14 finishes at 10:15; only then is its close available for the 10:15 check. With one-minute observations, the delay to the next check can be as much as 14 minutes.

2. A made-up example: how a pause disappears

The following prices and times are illustrative, not observations from the data. At 10:00, suppose the EMA has risen from 5,998 to 6,000 over its 180-bar comparison. The latest close is 6,010 versus 6,005 an hour earlier. Direction change is +2 points; momentum is +5 points. Both versions permit longs.

Illustrative timeUnderlying minute decisionEvery-minute permissionEvery-15-minute permission
10:00–10:07Allow longsAllow longsAllow longs, from the 10:00 check
10:07–10:08No new entries: momentum has turned negativePauseStill allow longs
10:08–10:15Allow longs againAllow longs againStill allow longs
10:15–10:30Allow longs throughoutAllow longsThe 10:15 check keeps longs allowed

From 10:00 to 10:30, the every-minute version has a 7-minute period and a 22-minute period, separated by one neutral minute. The held version has one 30-minute period. The pause did not disappear from the underlying calculation. The held decision ignored it.

The reverse can also happen. If the signal is neutral at 10:15 but resumes longs at 10:16, the held version stays neutral until 10:30. Checking less often can miss both interruptions and opportunities.

3. What exactly gets counted?

One uninterrupted period means consecutive measured minutes allowing the same nonzero direction. One neutral minute ends it. A direct change from long to short ends one period and starts another. Long permission restarting after a pause is another period.

Each day is measured from 9:30 a.m. inclusive to 4:00 p.m. exclusive: 390 one-minute intervals. The close at 9:30 supplies the first decision, based on the 9:29–9:30 candle. The final measured decision begins at 3:59 p.m. The close at 4:00 creates no extra measured minute.

A period already active at 9:30 is counted from 9:30. A period still active at 4:00 is cut off there. We do not join periods across days. These observed lengths are therefore not full lifetimes of every signal.

Periods per day = total observed periods / measured days
Median length = middle value of all observed period lengths
Short-period share (%) = periods lasting at most 30 minutes / all periods × 100
Days with a 3-hour period (%) = days with any period ≥ 180 minutes / all days × 100
Active-time share (%) = minutes allowing longs or shorts / all measured minutes × 100

If the period count is even, the median is the average of the two middle lengths. Neutral minutes count in measured time but are not active periods. A day without an active period would still count in the days denominator.

The 15-minute minimum is built into the slower schedule. Its decisions cannot change between quarter-hour checks, and the measured day also starts and ends on that grid. All its observed period lengths are multiples of 15 minutes. That is a property of the rule, not a newly discovered market pattern.

4. Results: fewer periods, similar total active time

Both columns use the same 342 days and 133,380 measured minutes. The eligible dates run from 2024-09-05 through 2026-08-28; the source archive itself spans August 28, 2024 through August 28, 2026. Percentages are rounded.

Measurement and denominatorCheck every minuteCheck every 15 minutes and hold
Days measured342342
Total uninterrupted periods4,2981,252
Average periods per day12.573.66
Middle observed length (median)4 minutes45 minutes
Periods lasting at most 30 minutes3,570 / 4,298 = 83.1%577 / 1,252 = 46.1%
Days containing a period of at least 3 hours15 / 342 = 4.4%55 / 342 = 16.1%
Minutes allowing long or short entries73,377 / 133,380 = 55.0%73,395 / 133,380 = 55.0%

The held version records 70.9% fewer periods: (4,298 − 1,252) / 4,298 × 100. Its active-time share is almost the same. In this sample, the main change is how active minutes are grouped, rather than a large increase in the total time permission is on.

Even after holding decisions, only 55 of 342 days contain a continuous 3-hour period. The middle period remains 45 minutes. This does not give a consistently all-day permission label.

5. What does the slower version ignore?

The two versions display different decisions for 21,297 of 133,380 measured minutes (16.0%). The denominator includes long, short and neutral minutes.

Type of disagreementMeasured minutes
Held version allows an entry; current minute signal is neutral10,618
Held version is neutral; current minute signal allows an entry10,600
Both are active but point in opposite directions79
Total different-decision minutes21,297

These mutually exclusive counts add to the total. They measure different labels, not forecast errors. We did not test whether the ignored changes helped or hurt a trade.

Practical meaning: a fixed decision schedule is a simple way to reduce interruptions. It exchanges responsiveness for steadier permission. If the goal is to profit from it, the next test needs explicit entry, exit, stop, fill and cost rules. None of those outcomes can be inferred from the period lengths.

6. Optional checks, exclusions and calculation files

Did the same pattern appear in the earlier and later dates?

We split the 342 selected dates into the first 171 and last 171. The split begins the later half on 2025-10-30. Periods per day and median length have the same definitions as above.

Eligible dates and day countEvery minuteEvery 15 minutes and hold
2024-09-05 to 2025-10-29
171 days
12.82 periods/day
3-minute median
3.66 periods/day
45-minute median
2025-10-30 to 2026-08-28
171 days
12.32 periods/day
4-minute median
3.66 periods/day
45-minute median

This is a descriptive consistency check. Both halves reuse the first article's data and were examined after the question was chosen. They are not a new untouched test or independent confirmation.

Which dates and observations were left out?

The licensed source contains 707,321 one-minute rows across 518 futures session dates, August 28, 2024–August 28, 2026. A futures session date includes its preceding evening.

  1. 485 dates have all 390 daytime bars and no source-marked bad observation anywhere in that session. The other 33 do not meet those requirements.
  2. Of those 485, 342 have valid history for every original comparison component throughout all daytime decision intervals. The other 143 do not.
  3. We keep those exact 342 days here, even though this follow-up needs only the minute-based signal. That makes it directly comparable with the original study, at the cost of excluding additional dates.

The source marks 8,846 unusable rows across 13 dates and has 96 within-session timestamp breaks. Indicators restart after an unusable bar, an internal missing minute or a selected-contract change. There are eight contract transitions. We use the original unadjusted contract prices and never invent replacement bars.

Scheduled daily, weekend and overnight closures do not reset the EMA. Its 180-bar comparison counts observed trading minutes across closures. Momentum requires two endpoints exactly 60 elapsed minutes apart. All hourly and 15-minute candles used for the original matched sample require every constituent minute.

The EMA starts from the first close in each uninterrupted calculation segment. It needs 3,600 observations before the initial EMA is usable, plus 180 more before its direction comparison is available. The original hourly comparison needs 60 complete hours plus three older hours. These initialization requirements contribute to exclusions.

What checks were actually performed?

On October 15, 2026, the original licensed archive was read without modification and its fingerprint matched the documented input. The unchanged first-study calculation was rerun. A separate period-counting implementation then matched 18 summary values: nine measurements for each decision schedule.

We checked all 342 days for exactly 390 consecutive measured intervals, checked that held decisions change only on quarter-hour boundaries, and reconciled the three disagreement categories. Five made-up tests check pauses, holding neutral decisions, direction changes and day-edge counting.

The separate recount starts from the same calculated minute signals. It checks the timing and summaries, not every source price or EMA value independently. Earlier arithmetic checks from the first study are not new independent evidence for this follow-up.

Limitations and untested questions

We tested one held schedule: every 15 minutes. Other schedules, different indicator lengths, trading returns and execution costs were not compared in this follow-up. We did not search for the schedule with the best profit. Our measurements include periods clipped at session boundaries. The selected days may differ from excluded days, and the input ends in August 2026.

A steady upward label can accompany sideways or falling prices. Holding permission is not the same as holding a position. Neither long durations nor few interruptions establish profitable trading.

Dig deeper: formulas, code, input schema and summarized results

The exact GitHub version of this package will be attached when the owner publishes. Original vendor prices are not redistributed. Full reproduction requires obtaining the documented licensed input; its fingerprint identifies a file, not public access to it.

Report prepared October 15, 2026. A verified timing follow-up on the first study's sample. All displayed percentages are rounded.
Study dates, sample and method
Data period
Aug 2024 – Aug 2026
Eligible sample
342 matched daytime sessions
Method
Same signal; different check schedule

JUMP TO ANYWHERE

Keep moving.